Vein Finder Stand Type SIFVEINSET-1.1

$2,695

Type: Vein Finder Stand Type: Vein finder + Fixed Stand

Light type: Infrared.

Depth: – Up to 10 mm in the hand with the help of an intensifier in the palm (accessory provided for free)

– 3 – 5 mm for legs and arms.

Best Projection Distance: 20cm~25cm.

Colors: Red, green, white,

Working modes: color adjustment, brightness adjustment, black and white reverse, pause, depth recognition, children mode

Assisting in: IV Contrast, Mesotherapy, Sclerotherapy, Blood Draw, Nasolabial Folds Injection, Botox Injection, Vascular procedures,…

Certification: FDA, CE.

For quantity discounts Please call +1-323 988 5889.

SKU: SIFVEINSET1.1 Categories: , ,

Vein Finder Stand Type SIFVEINSET-1.1

Main Unit SIFVEIN-5.2 + Fixed Stand SIFSTAND-2.0

 

Vein Finder Stand Type SIFVEINSET-1.1 consists of The fixed desk support SIFSTAND-2.0 to suit SIFVEIN-5.2 Vein Finder Imaging System. The fixed support is easily securable and allows for superficial venous blood vessels of patients to be rapidly evaluated and searched.

Consequently, the vein locator ensures medical staff can perform punctures during surgery and other medical procedures accurately and effectively.

Infrared vein detector acquires image of subcutaneous veins, the image which results from dealing with image signal is projected onto the surface of the skin. Thus, subcutaneous vein image will be displayed on the skin surface of the corresponding position.

The Vein finder is a medical observation tool, mainly composed of a main board, a display screen, a camera, a stand and a LED light source. the vein locator takes advantage of different absorption of near-infrared light with different wavelengths by oxyhemoglobin in surrounding tissues and vessels, after photoelectric conversion and image processing, the information is finally turned to be clear display of veins on the screen.

Therefore, the vein locator is used to find veins at ease, observe search for subcutaneous superficial blood vessels and for assisted puncture, such as assisted venous diagnosis and intravenous injection.

Furthermore, the vein locator detects subcutaneous superficial vein by infrared light of research of development patent technology, displaying situ image on the surface of the skin in order to help medical staff to check vascular orientation and distribution.

Features of the main unit SIFVEIN-5.2:

  • The Vein Locator SIFVEIN-5.21 uses a new type of optical structure design. That can realize the original position projection and improve the vein recognition rate.
  • Fully digital image acquisition and display mode.
  • Color adjustment: Red/ Green/ White Color Switch Mode.
  • Brightness Adjustment Feature.
  • Black and White reverse: Uses black and white inversion to adjust the switching between vein display and background color.
  • Depth identification: Provides More Specific Vein Location.
  • Child mode Function: pediatric vein finder

Specifications Of The Probe:

medical vein finder

Clinical Application:

  • Injecting Section – Helps intern nurses to complete injections. To solve the problem of injection difficulty for people of obesity, with small blood vessels or too dark skin, etc. whose veins are hard to find.
  • Cosmetology – For basic facial injections of hyaluronic acid, water light, botulinum toxin, collagen, etc. Avoid the serious consequences of injection errors.
  • Cardiology – Precise positioning for dissection of veins that is needed during bypass surgery.
  • Dialysis – Monitors the patient’s real-time blood flow during hemodialysis.
  • Peripheral angiography – lighting peripheral vessels of the patient and helping the doctor diagnose the condition.
  • And more departments that need to observe veins for diagnosis or experiments, in addition to universities, nursing colleges, laboratories, and so on. You can use a vein visualization device to help observe veins for assisted support.

Technical Parameters:

Technical Index:

  • Imaging method: DLP in-situ projection, no laser.
  • Maximum projection depth: Up to 10 mm in the hand with the help of an intensifier in the palm (accessory provided for free)Between 3 – 5 mm for legs and arms.
  • Infrared wavelength: 850NM.
  • Rated power: 25VA.
  • Stand-by time: ≥180min.
  • Charging time: 3H(Off state).
  • Image Resolution: 824*480.
  • Contrapuntal precision: ≤ 0.2mm.
  • Projection brightness: 1W20Lumens (adjustable).
  • Optimal imaging distance: 20cm-25cm.
  • Host weight: 0.5KG.
  • Length: 220mm.
  • Frame frequency: > 30 frame/s.
  • Projection color: white/green/ red light can be switched.
  • Working mode: color adjustment, brightness adjustment, black and white reverse, pause, depth recognition, children mode..
  • Processor: Inter ®Atom.
  • Operating environment: WIN8.1 operating system.
  • Bracket: table model / cart model (optional).

Software and hardware features:

  • Adopt a new type of optical structure design. Realize the in-situ projection and improve the vein recognition rate.
  • Multiple image enhancement algorithm. To make the veins otherwise difficult to distinguish clearly visible.
  • Depth recognition: The depth of the vein can be distinguished and hinted by the recognition of the grayscale.
  • Through the image acquisition, processing, transmission to achieve full digital and improve the drive circuit of the optical machine. Use high-performance computers. It can effectively improve the image quality and increase the frame frequency.
  • By using an innovative synchronous rectification power management circuit to Improve power conversion efficiency and reduce radiation and ripple.
  • Through the structural design of the centralized management and centralized heat dissipation of the heating device. Makes the whole machine dissipation better solved. Which ensures the stability of the machine for long time operation.

Application Cases:

A. Subcutaneous hemorrhage and vessel sealing:

vein detector

B. Venous sinus and varicosity:

vein locator

C. Newborn and coronary heart disease:

vein detector

D. Blood sampling and injection beauty needle:

medical vein finder

E. Phlebotomy:

Phlebotomists collect blood samples and units for laboratory tests, transfusions, donations, or research. Human health depends, to a large degree, on the precision and professionalism of Phlebotomists. Physicians diagnose major medical conditions based upon blood samples. Including many kinds of cancer, diabetes, thyroid disease, allergies, and pregnancy. In addition, donated blood and platelets collected at blood centers account for thousands of lives saved every year in California. It is the Phlebotomist who must safely collect blood samples. Identify them accurately and preserve them properly until needed for testing or transfusion.

There are three ways to collect blood using the vein finder SIFVEIN -5.2

  • Venipuncture (VP) is the most common means of collecting a blood specimen. It involves placing a needle in a vein. Typically at the bend of the arm or back of the hand.
  • Further, Skin punctures involve piercing skin tissue. That will bleed to collect a small amount of blood for minimal testing. An example; of a skin puncture would be a finger prick.
  • Furthermore, arterial blood gas puncture (commonly referred to as an ABG) involves drawing blood from an artery. Typically in the wrist. This kind of draw is rare and as a rule done on patients who have a respiratory condition.

medical vein finder

Working mode:

vein locator

Color Adjustment

It gives real projection vein image and high accuracy and switch’s color among RED, GREEN, WHITE for different skin condition.

vein locator

Brightness Adjustment

It regulates the brightness of vein image according to environment and reduces the outside impact in addition to providing an excellent image quality to adapt different condition.

vein detector

Black and white reverse

It switches the current vein and background color. In order, to make a clear contrast and enhance the vein positioning judgment.

vein locator

Depth Recognition

The vein locator gives a specific vein position mainly for stripping the accurate location of the vein in the heart bypass operation in Cardiology, etc.

vein finder

Child Mode

The vein detector reduces large-area projection interference and improves the success rate of puncture.

vein finder

The vein finder enable to perform promptly the necessary treatments and procedures for the patients

vein detector

The vein detector Helps prevent repetitive and wrong injections

vein locator

The vein locator enable to open previously saved images to compare before and after the treatment of the patient

medical vein finder

The vein finder can be used to various patients such as infants and obese patients regardless the color of the skin

vein finder

The medical vein finder enable to choose the right blooded vessel based on the precision of the video of the blood vessel

Specifications Of The Stand SIFSTAND-2.0:

medical vein findervein locator

Certifications:

FDA 

CE.

 

Vein Finder Stand Type SIFVEINSET-1.1

Main Unit SIFVEIN-5.2 + Fixed stand 

12 months warranty.

 

Related Articles 

Vein Finder Assisted Facial Countouring Botox InjectionsVein Viewers Ease The Pain of Elderly with COVID-19Vein Finder Use in Imaging Centers

 

Reviews

There are no reviews yet.

Be the first to review “Vein Finder Stand Type SIFVEINSET-1.1”

Your email address will not be published. Required fields are marked *

SIGN IN / REGISTER